Plumbing
Water Supply:
Don't forget to indicate hose bibs for parking, roofs & planters on Plumbing drawings.
The flow of water is as follows: City Main -> water meter -> from city main and from tanker -> both to water tank -> mechanical room.
Vent pipes must be indicated for all Toilets and Manholes.
Drain for all AC machines should be indicated in the drawing.
Pressurized pipe must be added to pump waste from the basement to the waste water Manhole pipe.
Thin Slit Linear gutters to be added in front of doors.
Drain must be through walls for all washing machines.
Swimming pool, Roof, and Outdoor areas/patios must also include drain points for cleaning.
Manhole location is as per municipality (Baladiya).
Recessed type FD (Floor Drain) is used for main areas that are covered with tiles.
PD (Planter Drain) is used for all planters and RD (Roof Drain) is used for roofs with slopes.
Reduce the number of Roding Eye (RE) to control sound and negative effects.
No RE on ground floor if there is no basement floor.
All plumbing drawings must show slopes.
Water Supply should be added for all washing machines.
Rain Drain in front of full openings shall be standard linear drains.
Floor Drain for Washrooms located underneath Wash Basin.
Kitchen Floor Drain located near Kitchen Sink.
No Floor Drain required in the Guest wash area.